Difference between revisions of "Talk:Indoor Thermostat"

From Free Knowledge Base- The DUCK Project: information for everyone
Jump to: navigation, search
(SEER Ratings: new section)
("Aux Ht" and "Em Ht": new section)
Line 22: Line 22:
  
 
SEER ratings are compiled using standard formulas to help you determine how much you can expect to pay annually in energy costs. This lets you compare air conditioning units and pick the one that best suits your needs.
 
SEER ratings are compiled using standard formulas to help you determine how much you can expect to pay annually in energy costs. This lets you compare air conditioning units and pick the one that best suits your needs.
 +
 +
== "Aux Ht" and "Em Ht" ==
 +
 +
Aux Ht or Auxiliary heat is the backup heat that turns on to help the compressor for first stage maintain your temperature setting. You know if the auxiliary heat is running when you see "Aux Heat On" in the thermostat's display. During this time both your Auxiliary heat and your compressor may be on at the same time. The thermostat will only run the Emergency Heat when the thermostat’s system switch is moved to the Em Ht position. When the thermostat is in this position the compressor does not run, only the Emergency heat runs. It is common that the Emergency heat and auxiliary or backup heat is the same source of heat (electric heat strips or fossil fuel).

Revision as of 23:25, 6 July 2022

Two-Stage Heat Pump

What is a two-stage heat pump?

A two-stage heat pump, also called a dual-stage heat pump, utilizes a two-stage compressor. It has 2 levels of intensity – high (100%) and low (typically 70%). The heat pump will cycle on and off at low speed — first stage — for the majority of the year, until it gets really cold or hot out and needs to jump to high speed — second stage — to keep up. The heat pump will automatically jump between stages in response to the temperature that you set on the thermostat.

How efficient are two-stage heat pumps?

Two-stage heat pumps are highly efficient: they consume less electricity at lower speeds and run for longer periods of time. Long run times circulate air throughout the home, eliminating the likelihood of hot and cold or humid and dry spots.

Once your home has reached your desired temperature, the system will switch to the first stage and continue to run. This fluctuation allows your home to efficiently maintain a steady, even temperature and humidity level.

SEER Ratings

All central ACs were required to have a minimum SEER rating of 10 in 1992 and by 2006 that minimum was raised to 13. In certain regions of the country, like the south and southwest, that minimum standard is raised even farther to 14.

In 2023, regulations will require a minimum SEER of 14 for the northern U.S. and 15 for the southern U.S.

Year	North	South & SW
1992	10	10
2006	13	13
2015	13	14
2023	14	15

SEER ratings are compiled using standard formulas to help you determine how much you can expect to pay annually in energy costs. This lets you compare air conditioning units and pick the one that best suits your needs.

"Aux Ht" and "Em Ht"

Aux Ht or Auxiliary heat is the backup heat that turns on to help the compressor for first stage maintain your temperature setting. You know if the auxiliary heat is running when you see "Aux Heat On" in the thermostat's display. During this time both your Auxiliary heat and your compressor may be on at the same time. The thermostat will only run the Emergency Heat when the thermostat’s system switch is moved to the Em Ht position. When the thermostat is in this position the compressor does not run, only the Emergency heat runs. It is common that the Emergency heat and auxiliary or backup heat is the same source of heat (electric heat strips or fossil fuel).