Coax Compression Connector Installation

Revision as of 23:48, 16 July 2015 by Admin (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

This is the F Type Compression connector being used by the satellite and cable television industry. The F Type compression connector should NOT be confused with earlier "screw on" or push on connectors that don't stay put. RG-6 Compression F-Connectors are secured into place by use of a special tool. They are designed for use with satellite and cable applications.


1 Strip back 3/4" down to the center wire. Be sure not to crush down insulator foam layer.

2 Carefully remove outer insulating sleeve another 1/4" back exposing braided shield. Do not damage braided shield wire.

Ftypecompression01.png

3 bend back the braided shield strands against outer sleeve at a 90 degree angle from the cable.

4 leave the tin part of the sleeve which is under the braiding intact against the foam insulation.

5 Slide compression fitting on over cable until foam insulation is visible on the front inner diameter but not extending past

6 Attach compression tool to compress fitting onto cable. Do not use excessive force. Compress only until black band is fully reduced..

7 Cut and remove excess inner core extending beyond front, leaving only a small amount extending.