Difference between revisions of "A/C Electrical Wiring Information for North America"
m |
m |
||
Line 32: | Line 32: | ||
Grounding rods are driven into the earth to a depth of at least 8 feet. If rock is hit at less than 8 feet, the grounding rod can be driven at an angle but the angle cannot exceed 45 degrees. A grounding rod can also be buried on top of rock in a trench that is 2 1/2 feet deep and 8 feet long. Ground clamps hold the ground conductor and the grounding rod together without losing conductivity when exposed to weather and movement. When the resistance of a single ground rod exceeds 25 ohms, an additional ground rod installed not less than 6 feet away is required. | Grounding rods are driven into the earth to a depth of at least 8 feet. If rock is hit at less than 8 feet, the grounding rod can be driven at an angle but the angle cannot exceed 45 degrees. A grounding rod can also be buried on top of rock in a trench that is 2 1/2 feet deep and 8 feet long. Ground clamps hold the ground conductor and the grounding rod together without losing conductivity when exposed to weather and movement. When the resistance of a single ground rod exceeds 25 ohms, an additional ground rod installed not less than 6 feet away is required. | ||
+ | |||
+ | === Switch and Receptacle Mounting Tips === | ||
+ | |||
+ | The height from the floor for the following: | ||
+ | * Electrical Outlet is 12" | ||
+ | * Light Switch is 48" | ||
+ | * Thermostat is 60" | ||
| |
Revision as of 10:24, 12 July 2008
Contents
Wire Color Standard
- White - Neutral ..... (grounded conductor, neutral conductor, neutral point) conductor with continuity to the electrical system's center tap of the power company transformer.
- Black - Hot 110v / 120v ..... (positive, live wire) not grounded, the active wire which is most likely to electrocute a person. This is the dangerous wire!
- Bare - Ground ..... (grounding wire, earth ground) a conductor with continuity to earth, may be bare or identified insulated wire of green or having green stripes.
- Red - Hot 110v / 120v
Electricity flows along the black "live" wire, feeding whatever is required and then returns along the white "neutral" wire to its local transformer. The flow can be interrupted by a switch installed on the black "live" wire for most common household applications.
Standard Wire
Earth Ground
A true earth ground, as defined by the National Electrical Code, physically consists of a conductive pipe or rod driven into the earth to a minimum depth of 8 feet.
A house ground is easy to find, all you have to do is look outside at the power feed coming in, there should be a thick bare wire coming down the side of the structure that attaches to either a steel pipe or a thick rod, driven into the ground. The neutral is tied to earth ground for lightning protection and to provide a path for any high voltage leakage from the power company's step down transformer. The ground is tied to the neutral to provide a return path to trip the breaker in the event of a fault. The main breaker box should be the only point where neutral/ground need to be connected, never at the outlets or other places in the electrical system.
Install Residential Grounding Rod
Grounding rods are driven into the earth to a depth of at least 8 feet. If rock is hit at less than 8 feet, the grounding rod can be driven at an angle but the angle cannot exceed 45 degrees. A grounding rod can also be buried on top of rock in a trench that is 2 1/2 feet deep and 8 feet long. Ground clamps hold the ground conductor and the grounding rod together without losing conductivity when exposed to weather and movement. When the resistance of a single ground rod exceeds 25 ohms, an additional ground rod installed not less than 6 feet away is required.
Switch and Receptacle Mounting Tips
The height from the floor for the following:
- Electrical Outlet is 12"
- Light Switch is 48"
- Thermostat is 60"